Laboratories

Tokai EMC Center

Emission Test (EMI), Immunity Test 
EMC testing for automotive electronics. Car manufacturers' own standards can be handled.

Accreditations:VLAC, VCA, Mazda

Tokai EMC center is EMC testing contains two labs. One is easy-to-access Kariya Ekimae Lab. located within just 5 minute walk from Kariya Station, another is Fujimatsu Lab. in the same Kariya City, 20 minutes away by car. Both labs are designed exclusively for EMC testing for automotive, military and aerospace electonics.

Especially we can offer you testing for most of the car manufactures' own test standards, also with noise suppression consulting if any.

All the chambers in the center are isolated each other and equipped with electronic security system to seal the confidential issue regarding customers' products under test.

Kariya Ekimae
Kariya Ekimae Lab.
Fujimatsu
Fujimatsu Lab.
entrance
Carry-in entrance (Kariya)
3m chamber
Anechoic chamber (Fujimatsu)
Shielded room
Shielded room (Kariya)
Kariya 3m chamber<
Inside of the 3m semi-anechoic chamber.(Kariya)

Test Facilities

※The number of the testing facilities represents the total amount of Kariya and Fujimatsu Lab.
Semi-anechoic Chamber for automotive parts 5
Shielded Room 6
Chamber with ground-plane floor
CISPR25 class5 possible. Magnetic field test available.
ISO11452-2 200MHz - 4GHz 300V/m possible
Rader pulse: 1200MHz - 1400MHz、2700MHz - 3000MHz 600V/m possible
Power supply: DC600V/25A、DC36V/100A
Internatonal standard and each car manufacturer's own standard can be handled. EV testing available.

Site Specifications

Anechoic Chambers

Chamber
 
Specifications
Anechoic Chamber
in Kariya-ekimae
(1 chamber)
Anechoic Chamber
in Fujimatsu
(2 chambers)
Facility Dimensions
(W × L × H)(m)
7.2 × 6.2 × 3.7
8.5 × 6.0 × 5.7
Product Entrance Dimensions
(W × H)(m)
1.2 × 2.0
1.2 × 1.8
Power Supply
Single phase
200V/100V
30A
60Hz
Three-phase Four lines
200V
50A
DC
DC35V 30A
DC600V 25A
DC 35V 30A
DC 500V 20A
Measurement Distance
1m
EUT Dimensions that can be carried in (m)
1.2 × 2.0
1.2 × 1.8
Copper-top Table Dimensions (m)
3 × 1(4 × 1)

Shielded Rooms

Chamber
 
Specifications
Shielded Room
(Kariya-ekimae,
3 rooms)
Shielded Room
(Fujimatsu,
1 room)
Facility dimensions
(W × L × H)(m)
6.0 × 4.0 × 2.3
6.8 × 4.0 × 2.7
Product Entrance Dimensions
(W × H)(m)
1.2 × 1.8
Power Supply
Single phase
200V/100V
30A
60Hz
Three-phase Four lines
200V
50A
DC
DC35V 30A
DC600V 25A
DC 35V 30A
DC 500V 20A
Measurement Distance
EUT Dimensions that can be carried in (m)
1.2 × 1.8
Copper-top Table Dimensions (m)
3 × 1(4 × 1)